Convert Gazepoint GSR resistance to conductance
Source:R/gsr-eda-helpers.R
convert_gazepoint_gsr_to_conductance.RdConverts GSR resistance values to conductance in microSiemens. The helper is
intentionally conservative. If a conductance column such as GSR_US is
already present, the data are returned unchanged unless overwrite = TRUE.
If input_unit = "auto", conversion is performed only when the source column
has a resistance-like name, such as GSR_OHMS or resistance_ohms.
Usage
convert_gazepoint_gsr_to_conductance(
data,
gsr_col = NULL,
output_col = "GSR_US",
input_unit = c("auto", "ohms", "kohms", "microsiemens"),
overwrite = FALSE
)Arguments
- data
A data frame.
- gsr_col
Optional source GSR column. If
NULL, a resistance-like column is detected when possible.- output_col
Name of the output conductance column.
- input_unit
Source unit.
"auto"converts only resistance-like columns;"ohms"converts ohms to microSiemens;"kohms"converts kilo-ohms to microSiemens;"microsiemens"copies values tooutput_col.- overwrite
Logical. If
FALSE, an existingoutput_colis not overwritten.
Value
The input data frame with a conductance column when conversion is
possible. A structured conversion summary is stored in the
gsr_conversion_summary attribute.
Details
Generic GSR columns are not automatically assumed to be resistance because
Gazepoint exports and workflows may represent GSR/EDA differently. For a
generic GSR column, use input_unit = "ohms" or input_unit = "kohms"
only when the study documentation confirms resistance units.
Examples
df <- data.frame(GSR_OHMS = c(1000000, 500000, NA))
convert_gazepoint_gsr_to_conductance(df)
#> GSR_OHMS GSR_US
#> 1 1e+06 1
#> 2 5e+05 2
#> 3 NA NA