Skip to contents

Detects negative time steps, duplicate time steps, non-finite time values, and recording segments within grouped Gazepoint biometric exports. This helper is intended for quality control and synchronization inspection. It does not alter raw values unless return_reindexed_time = TRUE, in which case an additional segment-relative time column is added.

Usage

audit_gazepoint_time_resets(
  data,
  time_col = NULL,
  group_cols = NULL,
  allow_ties = TRUE,
  split_on_negative_step = TRUE,
  return_reindexed_time = FALSE,
  min_segment_rows = 1
)

Arguments

data

A data frame containing Gazepoint biometric rows.

time_col

Optional time/counter column. If NULL, common Gazepoint time columns are detected automatically.

group_cols

Optional grouping columns. If NULL, available source/participant/media/trial-like columns are used.

allow_ties

Logical. If TRUE, repeated time values are not treated as non-monotonic.

split_on_negative_step

Logical. If TRUE, negative time steps start a new segment within each group.

return_reindexed_time

Logical. If TRUE, adds time_reindexed_within_segment, starting at zero within each detected segment.

min_segment_rows

Minimum rows expected per segment before a segment is flagged as short.

Value