Independent Vendor Validation and Semantic Fidelity
Source:vignettes/validation-evidence-0-7.Rmd
validation-evidence-0-7.RmdWhy import success is not validation
eyeprocess treats vendor compatibility as an evidence
claim. A file that can be read without error has established only parser
reachability. It has not shown that timestamps, coordinate systems, eye
identity, pupil units, event meanings, or missingness semantics survived
harmonisation.
Version 0.7 therefore adds a detailed evidence ladder:
eyeprocess::validation_evidence_levels()
#> rank level
#> 1 1 declared
#> 2 2 synthetic-fixture
#> 3 3 vendor-example
#> 4 4 independent-public-real
#> 5 5 multisession-multidevice-real
#> 6 6 semantic-roundtrip-validated
#> requirement
#> 1 Adapter or schema support is declared.
#> 2 Deterministic synthetic or package fixture passes the declared contract.
#> 3 A vendor-provided example export passes import and semantic checks.
#> 4 An independently produced public real recording passes the declared checks.
#> 5 Evidence spans repeated sessions and/or more than one device/model context.
#> 6 Native-to-canonical-to-interchange-to-canonical round trip has field-level semantic-loss evidence.The intended progression is:
declaredsynthetic-fixturevendor-exampleindependent-public-realmultisession-multidevice-realsemantic-roundtrip-validated
These detailed tiers complement, rather than replace, the package’s existing support-status mechanism.
Public validation corpus
The package does not auto-download public human-participant datasets. Use the manifest to review licences/terms and select cases deliberately.
corpus <- eyeprocess::public_validation_corpus()
corpus[, c("ecosystem", "device", "corpus", "evidence_goal", "access")]
#> ecosystem device
#> 1 Gazepoint GP3 HD 150 Hz
#> 2 Gazepoint GP3 HD 150 Hz
#> 3 EyeLink EyeLink (raw EDF; device metadata verify in corpus)
#> 4 EyeLink EyeLink 1000 1000 Hz
#> 5 EyeLink EyeLink Portable Duo 1000 Hz
#> 6 Tobii Tobii Pro Fusion 120 Hz
#> 7 Tobii Tobii Pro Glasses 3 ~50 Hz
#> 8 Pupil Labs Neon
#> corpus
#> 1 Pavia free observation of moving elements
#> 2 Pavia symmetric dynamic stimuli (2026)
#> 3 Raw eye-tracking data (EyeLink EDF; 10 subjects, 2026)
#> 4 GazeBase
#> 5 Eye movement benchmark data for smooth-pursuit classification (2026)
#> 6 MCFW-Gaze v3
#> 7 GroupAffect-4 v3
#> 8 Pupil Labs official Neon sample recording
#> evidence_goal
#> 1 independent-public-real; multisession-real; raw Gazepoint CSV
#> 2 independent-public-real; multisession-real; raw Gazepoint CSV
#> 3 raw-native-format; EDF parser validation
#> 4 large multisession longitudinal EyeLink benchmark
#> 5 raw EDF plus ASC conversion; event-parser benchmark
#> 6 remote-screen Tobii; binocular continuous raw gaze
#> 7 wearable Tobii; synchronized multimodal streams
#> 8 vendor-example; native/CSV semantic roundtrip
#> access
#> 1 public
#> 2 public; research/education/non-commercial terms
#> 3 public
#> 4 public CC BY 4.0
#> 5 public OSF
#> 6 public Zenodo
#> 7 public Zenodo; some audio restricted
#> 8 vendor exampleThe initial corpus targets two independent Gazepoint GP3 HD repeated-session sets, raw EyeLink EDF data, GazeBase, a 2026 EyeLink smooth-pursuit benchmark, Tobii Pro Fusion, Tobii Pro Glasses 3, and the official Pupil Labs Neon example.
Semantic round-trip contract
A strong test is not
native -> import succeeds
but
native vendor
-> eyeprocess canonical
-> BIDS eye tracking
-> eyeprocess canonical
-> field-by-field semantic comparison
Every compared field should be classified explicitly, for example as
LOSSLESS, UNIT_TRANSFORMED,
COORDINATE_TRANSFORMED,
SEMANTICALLY_EQUIVALENT, DERIVED,
UNSUPPORTED, INTENTIONALLY_DROPPED, or
AMBIGUOUS.
spec <- semantic_fidelity_spec(
timestamp_tolerance = 1e-6,
coordinate_tolerance = 1e-6,
pupil_tolerance = 1e-6
)
audit <- semantic_roundtrip_audit(
original = native_canonical,
roundtrip = bids_reimported,
key = c("recording_id", "sample_index"),
fields = c("timestamp", "gaze_x", "gaze_y", "pupil", "eye", "event")
)
semantic_loss_map(audit)
plot(audit)Timestamp semantics
Clock meaning is part of the schema. Device timestamps and system timestamps are not interchangeable merely because both are numeric.
timestamp_fidelity_audit(
source = imported_native,
roundtrip = imported_bids,
source_time = "device_time",
roundtrip_time = "device_time",
tolerance = 1e-6
)
validate_vendor_timestamp_semantics(imported_native)Coordinate and pupil fidelity
Coordinate transformations are acceptable when they are explicit and invertible. Silent transformations are evidence failures.
coordinate_fidelity_audit(
source = original,
roundtrip = transformed_back,
source_x = "gaze_x",
source_y = "gaze_y",
roundtrip_x = "gaze_x",
roundtrip_y = "gaze_y"
)
pupil_unit_fidelity_audit(
source = original,
roundtrip = transformed_back,
source_pupil = "pupil_left",
roundtrip_pupil = "pupil_left"
)BIDS eye-tracking semantics
BIDS 1.11.1 now specifies eye tracking under physiological
recordings. Among the important semantics are
PhysioType = "eyetrack", RecordedEye, and
SampleCoordinateSystem; gaze-on-screen recordings also
require screen presentation metadata.
validate_bids_eye_semantics() is a lightweight structural
audit for these requirements. It is intentionally not presented as a
replacement for the official BIDS validator.
validate_bids_eye_semantics(
data = bids_table,
metadata = bids_json
)HED event semantics
Event survival is not enough. An event that becomes
event_17 has preserved an identifier but may have lost
experimental meaning. HED provides a controlled, machine-actionable
event vocabulary.
event_semantics_audit(original_events, roundtrip_events,
key = "event_id", label = "trial_type", time = "timestamp")
validate_hed_event_semantics(events)validate_hed_event_semantics() performs only
package-level structural checks. For formal HED-schema validation, use
the official HED tooling.
Evidence matrix
base <- build_compatibility_matrix()
case_evidence <- data.frame(
ecosystem = "Gazepoint",
device = "GP3 HD",
evidence_level = "independent-public-real",
semantic_roundtrip_pass = FALSE
)
mat <- compatibility_evidence_matrix(base, case_evidence)
plot(mat)A vendor should be promoted only from retained evidence, not from undocumented manual impressions.